Shelly Pro 3EM 3CT 63
Device identification Device name: Shelly Pro 3EM 3CT63 Device model: SPEM-003CEBEU63 Device SSID: ShellyPro3EM3CT63-XXXXXXXX Device Bluetooth ID: 0x1025 Short description Shelly Pro 3EM-3CT63 (the Device) is a DIN rail mountable single or three-phase energy meter. Enhanced with all the gen2 firmware flexibility and LAN connectivity, it provides professional integrators with additional options for end-customer solutions. It can work standalone in a local LAN and/or Wi-Fi network, or it can also be operated through cloud home automation services through Modbus, MQTT, HTTP, and WebSocket. All inbound connections support TLS. The Device reports accumulated energy as well as instantaneous voltage, current, active, and apparent power per phase/channel in real time. It stores data in non-volatile memory that can be retrieved for a period of up to 60 days in 1-minute intervals. The Device has a real-time clock to keep the correct time if the connection to an SNTP server is lost. Shelly Pro 3EM-3CT63 can be accessed, set up, and monitored remotely by the User, as well as the Device can access and communicate with an automation system, as long as they are in the same network infrastructure. The Device has an embedded Web Interface which can be used to monitor and control the device, as well as adjust its settings. ⚠NOTICE! The Device does not have a built-in relay. Contactor control is provided using a Shelly Pro 3EM Switch Add-on attached to the Shelly Pro 3EM-3CT63. Main features 4 Quadrant measurement DIN rail mounting Multiple connection types: three phase or single phase installations Current transformer connection: non contact measurements. Phase sequence error detection1 (option) Channel-to-channel calibration2 No load threshold3 Optical pulse indication of energy usage Real-time clock: stored data keeps correct timestamps even if the internet connection is interrupted.4 Data logs: up to 60 days of data stored on the device for later retrieval External contactor control: loads can be controlled based on device automation or scripts. Available with the addition of the Shelly 3EM Switch Add-on Accuracy Class B (active energy)5 Photovoltaic ready 1 The Device has phase sequence error detection circuits. This detection works on phase voltages and considers only the zero crossings. The regular succession of these zero-crossing events is Phase A followed by Phase B followed by Phase C. If the sequence of zero-crossing events is, instead, Phase A followed by Phase C followed by Phase B, then a phase_sequence error is reported when the Phase sequence error detection option is enabled. 2 At least 500 W load is required for each channel. 3 In case the total load for the three channels drops below 30 VA per channel the measured power level will be displayed, but no consumed energy will be accumulated to the energy statistics and a No load threshold notification will be displayed in the Device web interface and the mobile application. 4 Shelly devices rely on internet connection for device clock. In case of installation network requirement or service interruption, the built-in clock provides correct timestamps for records. 5 The Device has a measurement accuracy of 1%, based on internal design validation and testing. Use cases Combined 3-phase current transformer (CT) that is designed to be mounted directly over a circuit breaker Industrial Power Distribution: In industrial settings with complex power distribution systems, a combined 3-phase CT mounted over a circuit breaker can efficiently measure and monitor current levels. This is crucial for optimizing energy usage and identifying potential issues in real-time. Commercial Buildings and Facilities: For commercial buildings and facilities, where space is often limited in electrical panels, the compact design of the CT is beneficial. Mounting it directly over circuit breakers allows for efficient use of space while ensuring accurate current measurement. Motor Control Centers (MCCs): Motor control centers, which are commonly found in manufacturing plants and industrial facilities, often have multiple circuit breakers. A combined 3-phase CT mounted over each breaker provides an integrated solution for monitoring motor currents, aiding in preventive maintenance and troubleshooting. Data Centers: In data centers, where precise monitoring of power consumption is crucial, combined 3-phase CTs can be installed over circuit breakers to measure the current flowing through critical equipment. Renewable Energy Installations: Combined 3-phase CTs can be used in renewable energy installations, such as solar or wind power systems. By mounting them directly over circuit breakers in the control panels, accurate current measurements can be obtained for monitoring and control purposes. Substation Monitoring: In electrical substations, where space is often at a premium, combined 3-phase CTs can be advantageous. Installing them directly over circuit breakers helps in monitoring the current levels in the different phases, contributing to the overall stability and reliability of the substation. Building Management Systems (BMS): For intelligent building management systems, having accurate real-time data on current consumption is essential. Combined 3-phase CTs can be installed over circuit breakers to provide the necessary information for energy management and demand response strategies. Power Quality Monitoring: In applications where maintaining power quality is critical, such as in sensitive electronic equipment or medical facilities, combined 3-phase CTs can be used to monitor current waveforms and identify any anomalies that might affect the quality of power supplied. Electrical Panel Upgrades: During electrical panel upgrades or retrofits, space constraints may arise. A combined 3-phase CT, designed for direct mounting over circuit breakers, offers a space-saving solution without compromising accurate current measurement. Smart Grid Deployments: In the context of smart grids, where real-time data is essential for grid management and optimization, combined 3-phase CTs can be deployed over circuit breakers to provide accurate current information for monitoring and control purposes. In each of these use cases, the combined 3-phase CT offers a space-efficient and integrated solution for current measurement, contributing to the overall efficiency, safety, and reliability of the electrical systems. Simplified internal schematics Device electrical interfaces Inputs 4 line inputs on screw terminals: 3 L and 1 N 4 current transformer inputs: 3 for L current measurements and 1 for N current measurement Ethernet port 1 RJ45 connector ⚠CAUTION! Plug in or unplug the LAN cable only when the Device is powered off! The LAN cable connector must not be metallic in the parts touched by the user to plug in or unplug the cable. Add-on interface Shelly proprietary serial interface ⚠CAUTION! High voltage on the add-on interface when the Device is powered! Detailed inputs and outputs description Connector to Shelly Pro 3EM-3CT63 three 2-pin MX3.0-2x1Y connectors Inputs 6 current transformer line inputs on screw terminals: 3 for + current measurements and 3 for - current measurement Connectivity Ethernet Wi-Fi Bluetooth Protocols Modbus MQTT RPC Safety function Internal temperature sensing and reporting Supported load types Resistive (incandescent bulbs, heating devices) Capacitive (LED light drivers, capacitor banks, electronic equipment, motor start capacitors) Inductive (transformers, fans, refrigerators, air-conditioners) User interface Inputs One tactile dome button Press briefly to toggle the state of the relay in the attached Shelly Pro 3EM Switch Add-on. Press and hold for 5 sec to activate Device AP. Press and hold for 10 sec to factory reset. Outputs LED indication Power: Red light if the power supply is connected. Wi-Fi (varies): Blue light if in AP mode. Red light if in STA mode, and not connected to a Wi-Fi network. Yellow light if in STA mode, and connected to a Wi-Fi network. Not connected to Shelly Cloud or Shelly Cloud disabled. Green light if in STA mode, and connected to a Wi-Fi network and the Shelly Cloud. The LED will be flashing Red/Blue if OTA update is in progress. LAN: Green light if LAN is connected. Count: Red light will be flashing when the Device is measuring energy according to settings with frequency dependent on the energy flowing through the measured circuit. Specifications Quantity Value Physical Size (HxWxD): Shelly Pro 3EM-3CT63: 94x19x69 mm / 3.70x0.75x2.71 in Shelly 3CT63: 14x54x26 mm / 0.55x2.12x1.02 in Weight: Shelly Pro 3EM-3CT63: 62 g / 2.19 oz Shelly 3CT63: 32 g /1.12 oz Screw terminals max torque: 0.4 Nm / 3.5 lbin Conductor cross section: Shelly Pro 3EM-3CT63: 0.5 to 2.5 mm² / 20 to 14 AWG Shelly 3CT63: 0.2 to 2.5 mm² / 24 to 14 AWG (solid, stranded, and bootlace ferrules) Conductor stripped length: 6 to 7 mm / 0.24 to 0.28 in Mounting: Shelly Pro 3EM-3CT63: DIN rail Shelly 3CT63: Freestanding on phase wires Conductor aperture Shelly 3CT63: Ø9 mm / Ø0.35 in Shell material: Plastic Shell color: White Environmental Ambient working temperature: -20°C to 40°C / -5°F to 105°F Humidity: 30% to 70% RH Max. altitude: 2000 m / 6562 ft Electrical Power supply: 100-260 V~ 50/60 Hz Power consumption: < 3 W External protection: Tripping characteristic B or C, 16A max. rated current, min. 6 kA interrupting rating, energy limiting class 3 Shelly 3CT63 electrical strength: 1000 V~, 60 sec Sensors, meters Internal-temperature sensor: Yes Voltmeter (AC): 100 - 260 V Voltmeter accuracy: ±1 % Ammeter (AC): 0 - 63 A Ammeter accuracy: ±1 % (2 - 63 A), ±2 % (1 - 2 A), ±5 % (0 - 1 A) Compatible current transformers: 3CT63 Power and energy meters: Active and apparent power Active and apparent energy Power factor Fundamental active and fundamental reactive energy Channel-to-channel calibration minimum load: 500 W per channel No load threshold: 30 VA per channel Measurement data storage: At least 60 days of 1 min data resolution Data export: CSV for PQ recorded values JSON format export through RPC Radio Wi-Fi Protocol: 802.11 b/g/n RF band: 2400 - 2495 МHz Max. RF power: < 20 dBm Range: Up to 30 m / 100 ft indoors and 50 m / 160 ft outdoors (Depends on local conditions) Bluetooth Protocol: 4.2 RF band: 2400 - 2483.5 MHz Max. RF power: < 4 dBm Range: Up to 10 m / 33 ft indoors and 30 m / 100 ft outdoors (Depends on local conditions) Microcontroller unit CPU: ESP32-D0WDQ6 Flash: 16 MB Firmware capabilities Webhooks (URL actions): 20 with 5 URLs per hook Scripting: Yes MQTT: Yes Scripting: Yes Encryption: Yes Basic wiring diagrams Fig. 1: Three-phase wiring diagram Fig. 2: Single-phase wiring diagram Legend Terminals Wires A: Phase A terminal LA: Phase A live (110-240 V~) wire B: Phase B terminal LB: Phase B live (110-240 V~) wire C: Phase C terminal LC: Phase C live (110-240 V~) wire N: Neutral terminal N: Neutral wire IA: Phase A current transformer input IB: Phase B current transformer input IC: Phase C current transformer input IN: Neutral current transformer input Current transformers 3CT63: 3-phase current transformer/63A CTN: Neutral current transformer (optional, not included) K->L: Direction of the primary current flow Installation Legend LA, LB, LC: Three-phase setup (3~) L: Single-phase setup (1~) RD: Red wire BK: Black wire K ->L: Direction of the primary current flow Shelly Smart Control Adding the device to the Shelly Smart Control Troubleshooting
€138.99
In stock